A Standard for the Measurement of Oxygen Transfer in Clean Water
This standard was developed to measure the rate of oxygen transfer from diffused gas and mechanical oxygenation devices to water. The standard is applicable to laboratory scale oxygenation...

Thermal Storage, Now and Future
Two-part article describes a 250 x 82 x 22 ft underground concrete tank that stores about 29,000 ton-hours of cooling effect for Yale University's medical school complex....

An Improved Design for Grain Storage Tanks Solves Problem of Brittle Failures
The welded tank features fracture-tough steel and tube stiffeners to overcome problems evident in several failures of major tanks in recent years. Used extensively for grain storage in...

Trouble Shooting ChemicaLly Resistant Masonry
This paper is a series of case histories showing specifically how lack of understanding of the nature of the materials and their proper uses has caused failure in design, specification,...

First U.S. Carrousel Racetrack Sewage Plant: simple, economical, excellent removeal.
Campbellsville, Kentucky will be the first community in the U.S. to use a promising new sewage treatment process�� the so-called Carrousel process. The process uses turbine aerators both...

A Cheap Solution to Pollution from Combined-Sewer Overflows
Every time it rains, the surface waters of many of the older communities around the U.S. are polluted by a mixture of sanitary waste and stormwater. The problem: when the community sewers...

Foundation Soil Preload Saves $164,000
Soils in the lower Mississippi valley are highly compressible and present a challenge to structural foundation designers. Rather than support power plant structures on piles, one design...

Trans Alaska Pipeline
This is one of the most extraordinary projects contending for the OCEA awards. Examples: the 360 mile haul road built in one summer; the 29 construction camps, self-contained cities to...

Condeep�In 400 Ft of Water, Concrete Caisson Requires No Piles
The Condeep structure consists of (1) 19 cylindrical tanks each 66-ft diam and 164-ft high that together will store up to 900,000 bbl of oil; (2) the extension upward 300-ft more of three...

Flow Equalization�Plus for Wastewater Treatment Plants
Flow equalization is important in maintaining optimum level performance in chemical water treatment plants. One way to do this is to build storage tanks upstream to regulate flow instead...

Structural Plastics
Properties and Possibilities
Proceedings of a Symposium at the National Structural Engineering Meeting held in Louisville, Kentucky, 1969. Sponsored by the Committee on Plastics of the Structural Division of the American...

 

 

 

 

Return to search